Dell Precision™ Workstations Fan Locations

Dell Precision™ Workstations Fan Locations

  Dell Precision Workstation 650 Computer

  Dell Precision Workstation 450 Computer

  Dell Precision Workstation 530 Computer

  Dell Precision Workstation 620 Computer

NOTE: Part numbers listed with each fan are subject to change.
NOTE: Overtemp indicates that the processor temperature has risen, and it does not necessarly indicate a fan failure.
NOTE: Thermtrip indicates a catastrophic failure.


Dell Precision Workstation 650 Computer

Error Messages

Fan Failure

Boot Message (F1/F2)

Event Log Message

AGP card-cage fan

During boot

Alert! Card-cage fan failure

<Date> <Time> Out of Range Card-cage Fan

Run time

On next boot: Alert! Previous fan failure

<Date> <Time> Out of Range Card-cage Fan

CPU 0 fan

During boot

Alert! CPU 0 Fan Failure

<Date) <Time> Out of Range CPU 0 Fan

Run time

On next boot: Alert! Previous fan failures

<Date> <Time> Out of Range CPU 0 Fan

CPU 1 fan

During boot

Alert! CPU 1 fan failure

<Date> <Time> Out of Range CPU 1 Fan

Run time

On next boot: Alert! Previous Fan Failure

<Date> <Time> Out of Range CPU 1 Fan

CPU 0 Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 0 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 0 Temperature

CPU 1 Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 1 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 1 Temperature

System Thermtrip

During boot

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

 

Run time

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

 

Power supply fan 1

During boot

Alert! Power supply fan failure

<Date> <Time> Out of Range Power Supply Fan 1

Run time

Alert! Previous fan failure

<Date> <Time> Out of Range Power Supply Fan 1

Power supply fan 2

During boot

Alert! Power supply fan failure

<Date> <Time> Out of Range Power Supply Fan 2

Run time

Alert! Previous fan failure

<Date> <Time> Out of Range Power Supply Fan 2

PN 0U231 — CPU fan, independently replaceable, two per system

1

CPU 1 fan

2

CPU 0 fan

PN 5M486 — AGP card cage fan

PN 1M475 — Power supply fan, 460W (dual fan power supply)

1

power supply fans (2)


Dell Precision Workstation 450 Computer

Error Messages

Fan Failure

Boot Message (F1/F2)

Event Log Message

CPU 0 fan

During boot

Alert! CPU 0 Fan Failure

<Date) <Time> Out of Range CPU 0 Fan

Run time

On next boot: Alert! Previous fan failures

<Date> <Time> Out of Range CPU 0 Fan

CPU 1 fan

During boot

Alert! CPU 1 fan failure

<Date> <Time> Out of Range CPU 1 Fan

Run time

On next boot: Alert! Previous Fan Failure

<Date> <Time> Out of Range CPU 1 Fan

CPU 0 Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 0 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 0 Temperature

CPU 1 Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 1 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous processor thermal failure

<Data><Time> Out of range CPU 1 Temperature

System Thermtrip

During boot

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

 

Run time

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

 

Power supply fan 1

During boot

Alert! Power supply fan failure

<Date> <Time> Out of Range Power Supply Fan 1

Run time

Alert! Previous fan failure

<Date> <Time> Out of Range Power Supply Fan 1

Power supply fan 2

During boot

Alert! Power supply fan failure

<Date> <Time> Out of Range Power Supply Fan 2

Run time

Alert! Previous fan failure

<Date> <Time> Out of Range Power Supply Fan 2

PN 7P974 — Dual CPU fans/shroud assembly

1

CPU 0 fan

2

CPU 1 fan

PN 2P222 — Power supply fan, 360W

1

power supply fans (2)


Dell Precision Workstation 530 Computer

Fan Failure

Boot Message (F1/F2)

Event Log Message

AGP card-cage fan

During boot

Alert! Card cage fan not detected

Out Of Range Card-cage Fan

Run time

On next boot: Alert! Previous fan failure

Out Of Range Card-cage Fan

CPU 0 fan

During boot

Alert! CPU 0 fan not detected

Out Of Range CPU 0 Fan

Run time

On next boot: Alert! Previous fan failure

Out Of Range CPU 0 Fan

CPU 1 fan

During boot

Alert! CPU 1 fan not detected

Out Of Range CPU 1 Fan

Run time

On next boot: Alert! Previous fan failure

Out Of Range CPU 1 Fan

CPU 0
Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Shutdown due to thermal event

Out Of Range CPU 0 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute

On next boot: Alert! Previous temperature failure at Processor 1

Out Of Range CPU 0 Temperature

CPU 1

Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous shutdown due to thermal event

Out Of Range CPU 1 Temperature

Run time

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous temperature failure at Processor 2

Out Of Range CPU 1 Temperature

Power supply fan 1

During boot

Alert! Power supply fan failure

Out Of Range Power Supply Fan 1

Run time

On next boot: Alert! Previous fan failure

Out Of Range Power Supply Fan 1

Power supply fan 2

During boot

Alert! Power supply fan failure

Out Of Range Power Supply Fan 2

Run time

On next boot: Alert! Previous fan failure

Out Of Range Power Supply Fan 2

System Thermtrip

During boot

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

Out Of Range CPU 0 Temperature

Run time

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event.

Out Of Range CPU 0 Temperature

System Thermtrip

During boot

System immediately shuts down!

On next boot: Previous shutdown due to thermal event

Out Of Range CPU 1 Temperature

Run time

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

Out Of Range CPU 1 Temperature

PN 929FF — CPU fan, independently replaceable, two per system

1

CPU 1 fan

2

CPU 0 fan

PN 0C252 — AGP card cage fan

PN 1M475 — Power supply fan, 460W

1

power supply fans (2)


Dell Precision Workstation 620 Computer

NOTE: Precision Workstation 620 computers do not have an event log.

Fan Failure

Boot Message (F1/F2)

AGP card-cage fan

During boot

No message

Run time

No message

CPU fan

During boot

Alert! CPU fan not detected

Run time

On next boot: Alert! Previous system fan failure

CPU 0
Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute.

On next boot: Alert! Previous shutdown due to thermal event

CPU 1
Overtemp

During boot

NOTE: The computer will shut down if this issue is not resolved within about 1 minute

On next boot: Alert! Previous temperature failure at Processor 1

System
Thermtrip

During boot

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

Run time

System immediately shuts down!

On next boot: Alert! Previous shutdown due to thermal event

Power supply fan 1

During boot

Alert! Power supply fan failure

Run time

On next boot: Alert! previous power supply fan failure

Power supply fan 2

During boot

Alert! Power supply fan failure

Run time

On next boot: Alert! Previous power supply fan failure

System fan (memory riser fan)

During boot

Alert! System fan not detected

Run time

On next boot: Alert! Previous system fan failure

PN D0744 — CPU/system fan (service kit to replace fan, not the bracket, which can be reused.)

PN 8329R — AGP fan

PN 7069P — Memory riser fan

1

memory riser fan

PN 41UFC — Power supply fans

1