Troubleshooting Your System: Dell PowerEdge SC440 Systems Hardware Owner's Manual

Back to Contents Page

Troubleshooting Your System

Dell™ PowerEdge™ SC440 Systems Hardware Owner's Manual

  Safety First—For You and Your System

  Start-Up Routine

  Checking the Equipment

  Troubleshooting Basic I/O Problems

  Troubleshooting a NIC

  Troubleshooting a Wet System

  Troubleshooting a Damaged System

  Troubleshooting the System Battery

  Troubleshooting Power Supply

  Troubleshooting System Cooling Problems

  Troubleshooting System Memory

  Troubleshooting a Diskette Drive

  Troubleshooting an Optical Drive

  Troubleshooting an IDE Tape Drive

  Troubleshooting a Hard Drive

  Troubleshooting a SAS RAID Controller

  Troubleshooting Expansion Cards

  Troubleshooting the Microprocessor



Safety First—For You and Your System

To perform certain procedures in this document, you must remove the system cover and work inside the system. While working inside the system, do not attempt to service the system except as explained in this guide and elsewhere in your system documentation.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

Start-Up Routine

Look and listen during the system's start-up routine for the indications described in Table 4-1.

Table 4-1. Start-Up Routine Indications 

Look/listen for:

Action

A code displayed on the system diagnostic indicators.

See "Diagnostic Lights" on page 15.

An error message displayed on the monitor.

See "System Messages" on page 16.

The monitor's power indicator.

See "Troubleshooting the Video Subsystem" on page 81.

The keyboard indicators.

See "Troubleshooting the Keyboard" on page 81.

The diskette drive activity indicator.

See "Troubleshooting a Diskette Drive" on page 89.

The CD drive activity indicator.

See "Troubleshooting an Optical Drive" on page 90.

The hard-drive activity indicator.

See "Troubleshooting a Hard Drive" on page 91.

An unfamiliar constant scraping or grinding sound when you access a drive.

See "Getting Help" on page 107.


Checking the Equipment

This section provides troubleshooting procedures for external devices attached to the system, such as the monitor, keyboard, or mouse. Before you perform any of the procedures, see "Troubleshooting External Connections" on page 80.

Troubleshooting IRQ Assignment Conflicts

Most PCI devices can share an IRQ with another device, but they cannot use an IRQ simultaneously. To avoid this type of conflict, see the documentation for each PCI device for specific IRQ requirements. Table 4-2 lists the IRQ assignments.

Table 4-2. IRQ Assignment Defaults 

IRQ Line

Assignment

IRQ0

System timer

IRQ1

Keyboard controller

IRQ2

Interrupt controller 1 to enable IRQ8 through IRQ15

IRQ3

Serial port 2 (COM2 and COM4)

IRQ4

Serial port 1 (COM1 and COM3)

IRQ5

Remote access controller

IRQ6

Diskette drive (optional) controller

IRQ8

Real-time clock

IRQ9

ACPI functions (used for power management)

IRQ10

Available

IRQ11

Available

IRQ13

Math coprocessor

IRQ14

IDE CD drive controller

IRQ15

Available

Troubleshooting External Connections

Loose or improperly connected cables are the most likely source of problems for the system, monitor, and other peripherals (such as a printer, keyboard, mouse, or other external device). Ensure that all external cables are securely attached to the external connectors on your system. See Figure 1-2 for the back-panel connectors on your system.

Troubleshooting the Video Subsystem

Problem
  • Monitor is not working properly.

Action
  1. Check the system and power connections to the monitor.

  2. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

If the tests run successfully, the problem is not related to video hardware.

If the problem is not resolved, see "Getting Help" on page 107.

Troubleshooting the Keyboard

Problem
  • System message indicates a problem with the keyboard.

  • Keyboard is not functioning properly.

Action
  1. Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program" on page 27.

  2. Examine the keyboard and its cable for signs of damage.

  3. Swap the faulty keyboard with a working keyboard.

If the problem is resolved, replace the faulty keyboard. See "Getting Help" on page 107.

  1. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

If the problem is not resolved, see "Getting Help" on page 107.

Troubleshooting the Mouse

Problem
  • System message indicates a problem with the mouse.

  • Mouse is not functioning properly.

Action
  1. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

If the test fails, continue to the next step.

  1. Examine the mouse and its cable for signs of damage.

If the mouse is not damaged, go to step 4.

If the mouse is damaged, continue to the next step.

  1. Swap the faulty mouse with a working mouse.

If the problem is resolved, replace the faulty mouse. See "Getting Help" on page 107.

  1. Enter the System Setup program and ensure that the USB port is enabled. See "Using the System Setup Program" on page 27.

If the problem is not resolved, see "Getting Help" on page 107.


Troubleshooting Basic I/O Problems

Troubleshooting a Serial Port

Problem
  • Error message indicates a problem with a serial port.

  • Device connected to a serial port is not operating properly.

Action
  1. Enter the System Setup program and ensure that the serial port is enabled and configured correctly for your application. See "Using the System Setup Program" on page 27.

  2. If the problem is confined to a particular application, see the application documentation for specific port configuration requirements that the program may require.

  3. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

If the tests run successfully but the problem persists, see "Getting Help" on page 107.

Troubleshooting a USB Device

Problem
  • System message indicates a problem with a USB device.

  • Device connected to a USB port is not operating properly.

Action
  1. Enter the System Setup program and ensure that the USB ports are enabled. See "Using the System Setup Program" on page 27.

  2. Turn off the system and any USB devices.

  3. Disconnect the USB devices, and connect the malfunctioning device to the other USB connector.

  4. Turn on the system and the reconnected device.

If the problem is resolved, the USB connector might be defective. See "Getting Help" on page 107.

  1. If possible, swap the interface cable with a working cable.

If the problem is resolved, replace the interface cable. See "Getting Help" on page 107.

  1. Turn off the system and the USB device, and swap the device with a comparable device.

  2. Turn on the system and the USB device.

If the problem is resolved, replace the USB device. See "Getting Help" on page 107.

If the problem persists, see "Getting Help" on page 107.


Troubleshooting a NIC

Problem
  • NIC cannot communicate with network.

Action
  1. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  2. Check the appropriate indicator on the NIC connector.

    • If the link indicator does not light, check all cable connections.

    • If the activity indicator does not light, the network driver files might be damaged or missing.

Remove and reinstall the drivers if applicable. See the NIC's documentation.

    • Change the autonegotiation setting, if possible.

    • Use another connector on the switch or hub.

If you are using a NIC card instead of an integrated NIC, see the documentation for the NIC card.

  1. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC's documentation.

  2. Enter the System Setup program and confirm that the NICs are enabled. See "Using the System Setup Program" on page 27.

  3. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed. See the network equipment documentation.

  4. Ensure that all network cables are of the proper type and do not exceed the maximum length.

If the problem persists, see "Getting Help" on page 107.


Troubleshooting a Wet System

Problem
  • Liquid spilled on the system.

  • Excessive humidity.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Remove all expansion cards installed in the system. See "Removing an Expansion Card" on page 56.

  4. Let the system dry thoroughly for at least 24 hours.

  5. Close the system. See "Closing the System" on page 41.

  6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the system does not start properly, see "Getting Help" on page 107.

  1. If the system starts properly, shut down the system and reinstall all of the expansion cards that you removed. See "Installing an Expansion Card" on page 57.

  2. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

If the tests fail, see "Getting Help" on page 107.


Troubleshooting a Damaged System

Problem
  • System was dropped or damaged.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Open the system. See "Opening the System" on page 41.

  2. Ensure that the following components are properly installed:

    • Expansion cards

    • Power supply

    • Fans

    • Processors and heat sinks

    • Optional installed drivers

    • Memory modules

  3. Ensure that all cables are properly connected.

  4. Close the system. See "Closing the System" on page 41.

  5. Run the system board tests in the system diagnostics. See "Running the System Diagnostics" on page 97.

If the tests fail, see "Getting Help" on page 107.


Troubleshooting the System Battery

Problem
  • System message indicates a problem with the battery.

  • System Setup program loses system configuration information.

  • System date and time do not remain current.

NOTE: If the system is turned off for long periods of time (for weeks or months), the NVRAM may lose its system configuration information. This situation is caused by a defective battery.
Action
  1. Re-enter the time and date through the System Setup program. See "Using the System Setup Program" on page 27.

  2. Turn off the system and disconnect it from the electrical outlet for at least one hour.

  3. Reconnect the system to the electrical outlet and turn on the system.

  4. Enter the System Setup program. See "Using the System Setup Program" on page 27.

If the date and time are not correct in the System Setup program, replace the battery. See "System Battery" on page 67.

If the problem is not resolved by replacing the battery, see "Getting Help" on page 107.

NOTE: Some software may cause the system time to speed up or slow down. If the system seems to operate normally except for the time kept in the System Setup program, the problem may be caused by software rather than by a defective battery.

Troubleshooting Power Supply

Problem
  • Power-supply fault indicator is blinking amber.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Check that the voltage selection switch on the back panel of the system is set properly. See "Power Supply Indicators" on page 15.

NOTICE: Setting the voltage selection switch to an improper setting can damage your system.
  1. Ensure that the power supply is properly installed by removing and reinstalling it. See "Installing the Power Supply" on page 70.

NOTE: After installing a power supply, allow several seconds for the system to recognize the power supply and to determine if it is working properly. The power indicator turns green to signify that the power supply is functioning properly.
  1. If the problem is resolved, close the system. See "Closing the System" on page 41.

If the problem persists, remove the faulty power supply. See "Removing the Power Supply" on page 69.

  1. Install a new power supply. See "Installing the Power Supply" on page 70.

If the problem persists, see "Getting Help" on page 107.


Troubleshooting System Cooling Problems

Problem
  • Systems management software issues a fan-related error message.

Action

Ensure that none of the following conditions exist:

  • System cover, drive blank, or front or back filler panel is removed.

  • Ambient temperature is too high.

  • External airflow is obstructed.

  • Cables inside the system obstruct airflow.

  • An individual cooling fan is removed or has failed. See "Troubleshooting a Fan" on page 87.

Troubleshooting a Fan

Problem
  • System-status indicator is amber.

  • System message indicates a fan-related error message.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Run the appropriate diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  3. Open the system. See "Opening the System" on page 41.

  4. Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "Cooling Fans" on page 65.

  5. Close the system. See "Closing the System" on page 41.

  6. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

  7. If the problem is not resolved, install a new fan. See "Cooling Fans" on page 65.

If the replacement fan is working properly, close the system. See "Closing the System" on page 41.

If the replacement fan does not operate, see "Getting Help" on page 107.


Troubleshooting System Memory

Problem
  • Faulty memory module.

  • Faulty system board.

  • Diagnostic indicator code indicates a problem with system memory.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  2. Turn off the system and attached peripherals, and then turn them on again.

If an error message does not appear, continue to the next step.

If an error message appears, go to step 11.

  1. Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" on page 27.

If the amount of memory installed matches the system memory setting, go to step 11.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Ensure that the memory banks are populated correctly. See "Memory Module Installation Guidelines" on page 59.

If the memory modules are populated correctly, continue to the next step.

  1. Reseat the memory modules in their sockets. See "Installing a Memory Module" on page 60.

  2. Close the system. See "Closing the System" on page 41.

  3. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

  4. Enter the System Setup program and check the system memory setting. See "Using the System Setup Program" on page 27. If the amount of memory installed still does not match the system memory setting, proceed to the next step.

  5. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

  6. Open the system. See "Opening the System" on page 41.

NOTE: Several configurations for the memory modules exist; see "Memory Module Installation Guidelines" on page 59.
  1. If a diagnostic test or error message indicates a specific memory module as faulty, swap or replace the module. Otherwise, swap the memory module in socket 1 with a module of the same type and capacity that is known to be good. See "Installing a Memory Module" on page 60.

  2. Close the system. See "Closing the System" on page 41.

  3. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.

  4. As the system boots, observe any error message that appears and the diagnostic indicators on the front of the system.

  5. If the memory problem is still indicated, repeat step 11 through step 16 for each memory module installed.

If the problem persists, see "Getting Help" on page 107.


Troubleshooting a Diskette Drive

Problem
  • Error message indicates a diskette drive problem.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Enter the System Setup program and verify that the diskette drive is configured correctly. See "Using the System Setup Program" on page 27.

  2. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  4. Open the system. See "Opening the System" on page 41.

  5. Ensure that the diskette drive interface cable is securely connected to the diskette drive and the system board.

  6. Ensure that a power cable is properly connected to the drive.

  7. Close the system. See "Closing the System" on page 41.

  8. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  9. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.

If the problem persists, continue with the following steps.

  1. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Remove all expansion cards installed in the system. See "Removing an Expansion Card" on page 56.

  4. Close the system. See "Closing the System" on page 41.

  5. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  6. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.

If the tests run successfully, an expansion card may be conflicting with the diskette drive logic, or an expansion card may be faulty. Continue to the next step.

If the tests fail, see "Getting Help" on page 107.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Reinstall one of the expansion cards you removed in step 12. See "Installing an Expansion Card" on page 57.

  4. Close the system. See "Closing the System" on page 41.

  5. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  6. Run the appropriate online diagnostic test to see whether the diskette drive works correctly.

  7. Repeat step 16 through step 21 until all expansion cards are reinstalled or one of the expansion cards causes the tests to fail.

If the problem is not resolved, see "Getting Help" on page 107.


Troubleshooting an Optical Drive

Problem
  • System cannot read data from a CD or DVD in an optical drive.

  • Optical drive indicator does not blink during boot.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Try using a different CD or DVD that you know works properly.

  2. Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the System Setup Program" on page 27.

  3. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  4. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  5. Open the system. See "Opening the System" on page 41.

  6. Ensure that the interface cable is securely connected to the optical drive and to the controller.

  7. Ensure that a power cable is properly connected to the drive.

  8. Close the system. See "Closing the System" on page 41.

  9. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help" on page 107.


Troubleshooting an IDE Tape Drive

Problem
  • System cannot read data from a tape in an IDE tape drive.

  • Diagnostic indicators or system messages indicate a tape drive-related failure.

  • Tape drive indicator (if applicable) does not blink during boot.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Try using a different tape that you know works properly.

If the problem persists, continue with the following steps.

  1. Enter the System Setup program and ensure that the drive's IDE controller is enabled. See "Using the System Setup Program" on page 27.

  2. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  3. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  4. Open the system. See "Opening the System" on page 41.

  5. Ensure that the IDE interface cable is securely connected to the tape drive and to the IDE connector on the system board.

  6. Ensure that a power cable is properly connected to the drive.

  7. Close the system. See "Closing the System" on page 41.

  8. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem is not resolved, see "Getting Help" on page 107.


Troubleshooting a Hard Drive

Problem
  • Device driver error.

  • One or more hard drives not recognized by the system.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
NOTICE: This troubleshooting procedure can destroy data stored on the hard drive. Before you proceed, back up all files on the hard drive.
  1. Run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on page 97.

Depending on the results of the diagnostics test, proceed as needed through the following steps.

  1. If you are experiencing problems with multiple hard drives, skip to step 5. For a problem with a single hard drive, continue to the next step.

  2. If your system has a SAS RAID controller, perform the following steps.

    1. Restart the system and press <Ctrl><R> to enter the host adapter configuration utility program.

See the documentation supplied with the host adapter for information about the configuration utility.

    1. Ensure that the hard drive has been configured correctly for the RAID.

    2. Exit the configuration utility and allow the system to boot to the operating system.

  1. Ensure that the required device drivers for your SAS controller card or SAS RAID controller are installed and are configured correctly. See the operating system documentation for more information.

  2. Check the cable connections inside the system:

    1. Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

    1. Open the system. See "Opening the System" on page 41.

    2. Verify that the cable connections between the hard drive(s) and the drive controller are correct, whether the connections are to the SATA connectors on the system board, a SAS expansion card, or a SAS RAID controller. See "Hard Drives" on page 51.

    3. Verify that the SAS or SATA cables are securely seated in their connectors.

    4. Close the system. See "Closing the System" on page 41.

    5. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, see "Getting Help" on page 107.


Troubleshooting a SAS RAID Controller

NOTE: When troubleshooting a SAS RAID controller, also see the documentation for your operating system and the controller.
Problem
  • Error message indicates a problem with the SAS RAID controller.

  • SAS RAID controller performs incorrectly or not at all.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Run the appropriate online diagnostic test. See "Using Dell PowerEdge Diagnostics" on page 97.

  2. Enter the System Setup program and ensure that the SAS RAID controller is enabled. See "Using the System Setup Program" on page 27.

  3. Restart the system and press <Ctrl><C> for the installed controller card to enter the configuration utility program.

See the controller's documentation for information about configuration settings.

  1. Check the configuration settings, make any necessary corrections, and restart the system.

If the problem is not resolved, continue to the next step.

  1. Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Ensure that the controller card is firmly seated into the system board connector. See "Installing an Expansion Card" on page 57.

  4. Verify that the cable connections between the hard drives and the SAS controller are correct. See "Hard Drives" on page 51.

Ensure that the cables are firmly connected to the SAS controller and the hard drives.

  1. Close the system. See "Closing the System" on page 41.

  2. Reconnect the system to its electrical outlet, and turn on the system and attached peripherals. If the problem persists, see "Getting Help" on page 107.


Troubleshooting Expansion Cards

NOTE: When troubleshooting an expansion card, see the documentation for your operating system and the expansion card.
Problem
  • Error message indicates a problem with an expansion card.

  • Expansion card performs incorrectly or not at all.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. Run the appropriate online diagnostic test for the expansion card which is exhibiting issues. See "Using Dell PowerEdge Diagnostics" on page 97. Follow any recommended actions provided by the diagnostics. If the problem persists, go to the next step.

  2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  3. Open the system. See "Opening the System" on page 41.

  4. Ensure that each expansion card is firmly seated in its connector. See "Installing an Expansion Card" on page 57.

  5. Close the system. See "Closing the System" on page 41.

  6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

If the problem persists, go to the next step.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Remove all expansion cards in the system. See "Removing an Expansion Card" on page 56.

NOTE: If your operating system is running off a disk controller card (such as a SAS controller card), do not remove it.
  1. Close the system. See "Closing the System" on page 41.

  2. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  3. Run the appropriate online diagnostic test for any item in the system that doesn't require an expansion card.

  4. If the problem persists, run the appropriate online diagnostic test on each card. See "Using Dell PowerEdge Diagnostics" on page 97.

    1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

    1. Open the system. See "Opening the System" on page 41.

    2. Remove an expansion card. See "Removing an Expansion Card" on page 56.

    3. Close the system. See "Closing the System" on page 41.

    4. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

    5. Run the appropriate online diagnostic test.

If the tests fail, repeat step 13 for each expansion card until you are able to single out the faulty expansion card.

If the tests fail for all expansion cards, see "Getting Help" on page 107.


Troubleshooting the Microprocessor

Problem
  • Error message indicates a processor problem.

  • Diagnostic indicator code indicates a problem with the processor or system board.

  • A heat sink is not installed for the processor.

Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.
  1. If possible, run the appropriate online diagnostics test. See "Using Dell PowerEdge Diagnostics" on page 97.

  2. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  3. Open the system. See "Opening the System" on page 41.

  4. Ensure that the processor and heat sink are properly installed. See "Replacing the Processor" on page 65.

  5. Close the system. See "Closing the System" on page 41.

  6. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  7. If possible, run the appropriate online diagnostic test. See "Running the System Diagnostics" on page 97.

If the tests fail or the problem persists, continue to the next step.

  1. Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

  2. Open the system. See "Opening the System" on page 41.

  3. Replace the processor. See "Replacing the Processor" on page 65.

  4. Close the system. See "Closing the System" on page 41.

  5. Reconnect the system to the electrical outlet, and turn on the system and attached peripherals.

  6. Run the appropriate online diagnostic test. See "Running the System Diagnostics" on page 97.

If the problem persists, the system board is faulty. See "Getting Help" on page 107.