System Codes and Messages: Dell Dimension 4100 System Reference
Back to Contents Page

System Codes and Messages: Dell™ Dimension™ 4100 System Reference

Diagnostic Codes
POST Beep Codes
System Messages

Diagnostic Codes

Your computer is equipped with four diagnostic lights, which are labeled "A," "B," "C," and "D" on the back of the computer. Each of the four lights can be yellow, green, or off as shown in Table 1. When the computer is turned on or restarted and it is functioning normally, the lights flash during power-on self-test (POST). After the computer starts, the lights remain green to signify normal computer operation.

If a malfunction is detected and the computer fails to start, the lights display a code that identifies the problem. Write down the diagnostic code displayed and look it up in Table 1.

Table 1. Diagnostic Codes

Diagnostic Code Definition Corrective Action
Power up default. Make sure that the computer is connected to a known working electrical outlet, and then check whether the front-panel power light is on or off. If the power light is off, check the power supply. If the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.

See Precautionary Measures, and then remove all cards. If the computer still does not start, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.

System board is receiving power, but the BIOS is not executing. Set the configuration jumper to Maintenance mode, and restart the computer. Exit and save changes in the system setup program. Turn off the computer and reset the configuration jumper to Normal mode, and then restart the computer.

See Precautionary Measures, and then remove all cards and restart the computer to determine if a resource conflict exists. If a conflict exists, resolve the conflict. If the problem  persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.

Recovery mode from BIOS failure. Set the configuration jumper to Maintenance mode and restart the computer. Exit and save changes in the system setup program. Turn off the computer and reset the configuration jumper to Normal mode, and then restart the computer.

See Precautionary Measures, and then remove all cards and restart the computer to determine if a resource conflict exists. If a conflict exists, resolve the conflict. If the problem  persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.

Microprocessor has failed a BIOS test. If the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
Memory failed to be sized or enabled. Reseat the memory modulesIf the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
PCI bus failure has occurred. See Precautionary Measures, and then remove all cards and restart the computer to determine if a resource conflict exists. If a conflict exists, resolve the conflict. If the problem still persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
Video controller failed to initialize or respond. Reseat the video card. If the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
IDE bus failure has occurred. Reseat the IDE cables. If the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
USB port or a device connected to it has failed initialization. Disconnect the device from the USB connector. If the problem persists, see "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
Other failure. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
Computer has started and turned over control to the operating system. No action is necessary.
NOTE: The Glossary defines abbreviations and acronyms.

 


POST Beep Codes

If the monitor cannot display errors or problems, during POST the computer might emit a series of beeps, or beep code, that identifies the problem. Table 2 lists the POST beep codes.

Table 2. POST Beep Codes

Beep Codes Possible Cause Corrective Action
1 A memory refresh failure occurred. Reseat the memory modules.
2 Memory parity cannot be reset. Reseat the memory modules.
3 A failure occurred in the first 64-KB of memory. Reseat the memory modules.
4 The system timer is not operational. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
6 8042 Gate A20 cannot be toggled. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
7 An exception interrupt error occurred. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
8 A read/write error occurred in the display memory. Reseat the video card.
10 A CMOS shutdown register test error occurred. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
11 An invalid BIOS is installed. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
NOTE: The Glossary defines abbreviations and acronyms.

 


System Messages

The first column in Table 3 lists (in alphabetical order) system messages that might appear on the screen during the boot routine or during normal system operation. The second column in the table lists probable causes of the messages, and the third column either provides a corrective action or refers you to a source for resolving the problem.

Table 3. System Messages

Message Possible Cause Corrective Action
8042 Gate-A20 error The keyboard controller failed its test. If you receive this message after making changes in the system setup program, enter the program and restore the original value(s).
Address Line Short! Error in the address decoding circuitry in the memory. Reseat the memory modules.
C: Drive Error

C: Drive Failure

The hard drive is not working or is not configured correctly. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program.
Cache Memory Bad, Do Not Enable Cache Cache memory is not operating. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
CH-2 Timer Error An error is occurring on the timer on the system board. See "Contacting Dell" in the Solutions Guide for instructions on obtaining technical assistance.
CMOS Battery State Low

CMOS Checksum Failure

CMOS System Options Not Set

CMOS Display Type Mismatch

CMOS Memory Size Mismatch

CMOS Time and Date Not Set

The system configuration information in the system setup program is incorrect, or the battery charge may be low. Enter the system setup program and verify the system configuration; then restart the computer.
Diskette Boot Failure Drive A or B is present but has failed the BIOS POST. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program. Check the interface cable at both ends.
DMA Error

DMA 1 Error

DMA 2 Error

Error in the DMA controller on the system board. The keyboard or system board may need to be replaced.
FDD Controller Failure

HDD Controller Failure

BIOS cannot communicate with the floppy drive or hard drive controller. Ensure that the drive is installed correctly in the computer and defined correctly in the system setup program. Check the interface cable at both ends.
INTR1 Error

INTR2 Error

Interrupt channel on the system board failed to POST. The keyboard or system board may need to be replaced.
Invalid Boot Diskette The operating system cannot be located on drive A or drive C. Enter the system setup program and confirm that drive A or drive C is properly identified.
Keyboard Error The BIOS has detected a stuck key. Make sure that nothing is resting on the keyboard; if a key appears to be stuck, carefully pry it up. If the problem persists, you may need to replace the keyboard.
KB/Interface Error An error occurred with the keyboard connector. The keyboard or system board may need to be replaced.
No ROM Basic The operating system cannot be located on drive A or drive C. Enter the system setup program and confirm that drive A or drive C is properly identified.
NOTE: The Glossary defines abbreviations and acronyms.

 