| Message |
Possible Cause |
Corrective Action |
| CMOS Battery Bad |
The system board battery may be faulty. |
Replace the system battery.
|
| CMOS Checksum Error |
A CMOS checksum error has occurred. |
Run the System Board Devices tests in
the Dell Diagnostics. |
| Diskette Drive x Error Diskette Drive Controller Error |
The diskette drive may be faulty, not configured
correctly in the system setup program, or not installed correctly. |
Run the Diskette tests in the Dell Diagnostics. |
| Equipment Configuration Error |
The hardware configuration does not match the system
setup program configuration data. |
Check the system setup program settings. |
| Expansion ROM Allocation Fail |
An expansion ROM on an expansion card was not loaded
correctly. |
Turn off the computer, and disconnect your system and
devices from their electrical outlets. Remove all of the expansion cards. Reconnect the
system and devices, and reboot the computer. If the problem persists, the expansion card
may be malfunctioning. If the message does not appear, turn off the system and reinsert
the other card. |
| IDE Drive n Error IDE Drive n Auto Detection Failed |
The IDE drive may be faulty, not configured correctly
in the system setup program, or not installed correctly. |
Run the IDE Devices tests in the Dell Diagnostics. |
| I/O Parity Error |
The I/O address is not correct. |
Run the System Board Devices tests in
the Dell Diagnostics. |
| Insert System Diskette and Press <Enter>
to Reboot |
The diskette in the diskette drive or the hard-disk
drive does not have a bootable operating system installed on it. |
Either replace the diskette with one that has a
bootable operating system, or remove the diskette from the diskette drive and restart the
computer. |
| IRQ Setting Error |
An IRQ conflict has occurred. |
See Resolving Software and Hardware
Incompatibilities in Chapter 4 of the Dell Dimension C System Reference and
Troubleshooting Guide. |
| Keyboard Interface Error Keyboard Error or Keyboard Not Connected
Keyboard Locked |
The keyboard cable may be loose or the keyboard/mouse
controller may be faulty. |
Check the connection of the keyboard cable to the keyboard connector on the back of the computer. If the
problem persists, run the Keyboard tests in the Dell Diagnostics. |
| Memory Error at MMMM:SSSS:OOOO (R:xxxxh,
W:xxxxh) |
One or more DIMMs may be improperly seated or faulty. |
Reseat the DIMMs. |
| NVRAM Checksum Error |
A NVRAM checksum error has occurred. |
Run the System Board Devices tests in
the Dell Diagnostics. If the tests do not identify the problem, clear NVRAM to set the system to its defaults. |
| On Board Serial Port 1 Conflict(s) On Board Parallel Port Conflict(s) |
The serial or parallel port on the system board has an
address conflict with an expansion card. |
See Resolving Software and Hardware
Incompatibilities in Chapter 4 of the Dell Dimension C System Reference and
Troubleshooting Guide. |
| On Board xxx ... Conflict(s) |
A device on the system board has an address conflict
with another device. |
See Resolving Software and Hardware
Incompatibilities in Chapter 4 of the Dell Dimension C System Reference and
Troubleshooting Guide. |
| PCI Device Error |
A device on the PCI bus may be faulty. |
Turn off the computer, and disconnect your system and
devices from their electrical outlets. Remove all of the expansion cards
Reconnect the system and devices and reboot the computer. If the problem persists, the
expansion card may be malfunctioning. If the message does not appear, turn off the system
and reinsert the other card. |
| Pointing Device Error Pointing Device Interface Error |
The mouse cable may be loose, or the keyboard/mouse
controller may be faulty. |
Check the connection of the mouse cable to the mouse
connector on the back of the computer. If the problem persists, run the Mouse
tests in the Dell Diagnostics. |
| Pointing Device IRQ Conflict |
The mouse controller on the system board has an IRQ
conflict with another device. |
See Resolving Software and Hardware
Incompatibilities in Chapter 4 of the Dell Dimension C System Reference and
Troubleshooting Guide. |
| Press <Del> Key to Enter SETUP or F1 Key
to Continue... |
A system configuration error has been detected, or the
hardware configuration does not match the settings in the system setup program. |
Verify that the settings in the system setup program
are correct. |
| Press <Del> to Turn Off NMI, or Any Key to
Reboot |
A nonmaskable interrupt (NMI) has occurred. |
Press carat (^) to reject the NMI error, or press any
other key to restart the system. |
| RAM Parity Error |
One or more DIMMs may be faulty or improperly seated. |
Reseat the DIMMs. |
| Real Time Clock Error |
A real-time clock error has occurred. |
Run the System Board Devices tests in
the Dell Diagnostics. |
| System Management Memory Bad |
One or more DIMMs may be faulty or improperly seated. |
Reseat the DIMMs. |
| System Resource Conflict |
Two devices in the system are attempting to use the
same resource. |
See Resolving Software and Hardware
Incompatibilities in Chapter 4 of the Dell Dimension C System Reference and
Troubleshooting Guide. |
| NOTE: The Glossary
defines abbreviations and acronyms. |