The tables in this appendix indicate how the status of lower-level storage components is "rolled up" into the combined status displayed for the controller or other higher-level component. The examples provided by these tables do not cover all scenarios, but they do indicate how status is rolled up when a particular component is in a healthy, degraded, or failed state.
Health Status Rollup: Battery is Charging or Dead
Table
B-1. Health Status Rollup: Battery is Charging or Dead (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/ Driver
Virtual Disk(s)
Component Status
Health Rollup
Not Applicable
Not Applicable
Not Applicable
Not Applicable
Not Applicable
Health Status Rollup: Physical Disks in a Virtual Disk are Failed or Removed
Table
B-2. Health Status Rollup: Physical Disks in a Virtual Disk are Failed or Removed (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/ Driver
Virtual Disk(s)
Component Status
Health Rollup
Health Status Rollup: Physical Disks in a Virtual Disk are Unsupported, Partially or Permanently Degraded
Table
B-3. Health Status Rollup: Physical Disks in a Virtual Disk are Unsupported, Partially or Permanently Degraded (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/ Driver
Virtual Disk(s)
Component Status
Health
Rollup
Health Status Rollup: All Physical Disks in a Virtual Disk are in Foreign State
Table
B-4. Health Status Rollup: All Physical Disks in a Virtual Disk are in Foreign State (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/ Driver
Virtual Disk(s)
Component Status
Not Applicable
Health Rollup
Not Applicable
Health Status Rollup: Some Physical Disks in a Virtual Disk are in Foreign State
Table
B-5. Health Status Rollup: Some Physical Disks in a Virtual Disk are in Foreign State (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/ Driver
Virtual Disk(s)
Component Status
Health Rollup
Health Status Rollup: Virtual Disk is Degraded; Physical Disks are Failed or Rebuilding
Table
B-6. Health Status Rollup: Virtual Disk is Degraded; Physical Disks are Failed or Rebuilding (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/Driver
Virtual Disk(s)
Component Status
Health Rollup
Health Status Rollup: Virtual Disk is Failed
Table
B-7. Health Status Rollup: Virtual Disk is Failed (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/Driver
Virtual Disk(s)
Component Status
Health Rollup
Health Status Rollup: Unsupported Firmware Version
Table
B-8. Health Status Rollup: Unsupported Firmware Version (Enclosures Not Included)
Storage Subsystem
Controller
Battery
Connector
Physical Disk(s)
Firmware/Driver
Virtual Disk(s)
Component Status
Health Rollup
Health Status Rollup: Enclosure Power Supply Failed or Power Connection Removed
Table
B-9. Health Status Rollup: Enclosure Power Supply Failed or Power Connection Removed
Storage Subsystem
Controller
Connector
Enclosure
Enclosure Power Supply
Virtual Disks
Physical Disks
Component Status
Health Rollup
Not Applicable
Not Applicable
Not Applicable
Health Status Rollup: One Enclosure Fan is Failed
Table
B-10. Health Status Rollup: One Enclosure Fan is Failed
Storage Subsystem
Controller
Connector
Enclosure
Enclosure Fan
Virtual Disks
Physical Disks
Component Status
Health Rollup
Not Applicable
Not Applicable
Not Applicable
Health Status Rollup: One Enclosure EMM is Failed
Table
B-12. Health Status Rollup: One Enclosure EMM is Failed
Storage Subsystem
Controller
Connector
Enclosure
Enclosure EMM
Virtual Disks
Physical Disks
Component Status
Health Rollup
Not Applicable
Health Status Rollup: One Enclosure Temperature Probe is Failed
Table
B-13. Health Status Rollup: One Enclosure Temperature Probe is Failed
Storage Subsystem
Controller
Connector
Enclosure
Enclosure Temperature Probe
Virtual Disks
Physical Disks
Component Status
Health Rollup
Not Applicable
Health Status Rollup: Lost Both Power Connections to the Enclosure
Table
B-14. Health Status Rollup: Lost Both Power Connections to the Enclosure
Storage Subsystem
Controller
Connector
Enclosure
All Enclosure Components
Virtual Disks
Physical Disks
Component Status
Not Applicable
Not Applicable
Health Rollup
Not Applicable
Not Applicable
Not Applicable
Health Status Rollup: One or More Physical Disks are Failed
Table
B-15. Health Status Rollup: One or More Physical Disks are Failed
Storage Subsystem
Controller
Connector
Enclosure
Enclosure Physical Disk(s)
Virtual Disks
Physical Disks
Component Status
Health Rollup
Not Applicable
Not Applicable
Health Status Rollup: Physical Disk is Rebuilding
Table
B-16. Health Status Rollup: Physical Disk is Rebuilding