Manuals

Manuals
Baseboard Management Controller Group: Dell OpenManage Server Administrator Version 5.2 SNMP Reference Guide

Back to Contents Page

Baseboard Management Controller Group

Dell™ OpenManage™ Server Administrator Version 5.2 SNMP Reference Guide

  Baseboard Management Controller Group Tables

  Baseboard Management Controller Group Variable Values


The Baseboard Management Controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and log events when certain parameters exceed their preset thresholds. The BMC Group provides information about the BMC that may be present in your system. In addition to providing general information about the BMC, this group provides information about the serial and local area network (LAN) interfaces of the BMC.


Baseboard Management Controller Group Tables

The objects in the BMC group define information about the BMC and the serial and LAN interfaces that can be used to access the BMC remotely to perform management activities. Objects for the serial interface define the serial connection mode, flow control type and bit rate. Objects for the LAN interface define the media access control (MAC) address, internet protocol (IP) address, subnet mask and default gateway.

The following MIB tables define the BMC group:

  • Baseboard Management Controller Table

  • Baseboard Management Controller Serial Interface Table

  • Baseboard Management Controller LAN Interface Table

Baseboard Management Controller Table

Name

bmcTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.10

Description

Defines the Baseboard Management Controller Table.

Syntax

SEQUENCE OF BmcTableEntry

Access

Not accessible

BMC Table Entry

Name

bmcTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1

Description

Defines the Baseboard Management Controller (BMC) Table Entry.

Syntax

BmcTableEntry

Access

Not accessible

Index

bmcChassisIndex, bmcIndex

BMC Chassis Index

Name

bmcChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BMC Index

Name

bmcIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.2

Description

Defines the index (one-based) of the BMC.

Syntax

DellObjectRange

Access

Read-only

BMC State Capabilities

Name

bmcStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.3

Description

Defines the state capabilities of the BMC.

Syntax

DellStateCapabilities

Access

Read-only

BMC State Settings

Name

bmcStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.4

Description

Defines the state settings of the BMC.

Syntax

DellStateSettings

Access

Read-write

BMC Status

Name

bmcStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.5

Description

Defines the status of the BMC.

Syntax

DellStatus

Access

Read-only

BMC Display Name

Name

bmcDisplayName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.6

Description

Defines the display name of the BMC.

Syntax

DellString

Access

Read-only

BMC Description Name

Name

bmcDescriptionName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.7

Description

Defines the description of the BMC.

Syntax

DisplayString (SIZE (0..255))

Access

Read-only

BMC IPMI Version Name

Name

bmcIPMIVersionName

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.8

Description

Defines the version of the Intelligent Platform Management Interface (IPMI) specification that the BMC supports.

Syntax

DellString

Access

Read-only

BMC GUID

Name

bmcGUID

Object ID

1.3.6.1.4.1.674.10892.1.1900.10.1.9

Description

Defines the Globally Unique ID (GUID) of the BMC.

Syntax

OCTET STRING (SIZE(16))

Access

Read-only

Baseboard Management Controller Serial Interface Table

Name

bmcSerialInterfaceTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.20

Description

Defines the BMC Serial Interface Table.

Syntax

SEQUENCE OF BmcSerialInterfaceTableEntry

Access

Not accessible

BMC Serial Interface Table Entry

Name

bmcSerialInterfaceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1

Description

Defines the BMC Serial Interface Table Entry.

Syntax

BmcSerialInterfaceTableEntry

Access

Not accessible

Index

bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex

BMC Serial Interface Chassis Index

Name

bmcSerialInterfaceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BMC Serial Interface BMC Index

Name

bmcSerialInterfaceBMCIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.2

Description

Defines the index (one-based) of the associated BMC.

Syntax

DellObjectRange

Access

Read-only

BMC Serial Interface Index

Name

bmcSerialInterfaceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.3

Description

Defines the index (one-based) of the BMC serial interface.

Syntax

DellObjectRange

Access

Read-only

BMC Serial Interface State Capabilities

Name

bmcSerialInterfaceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.4

Description

Defines the state capabilities of the BMC serial interface.

Syntax

DellStateCapabilities

Access

Read-only

BMC Serial Interface State Settings

Name

bmcSerialInterfaceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.5

Description

Defines the state settings of the BMC serial interface.

Syntax

DellStateSettings

Access

Read-write

BMC Serial Interface Status

Name

bmcSerialInterfaceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.6

Description

Defines the status of the BMC serial interface.

Syntax

DellStatus

Access

Read-only

BMC Serial Interface Channel Number

Name

bmcSerialInterfaceChannelNumber

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.7

Description

Defines the BMC channel number of the BMC serial interface.

Syntax

DellUnsigned8BitRange

Access

Read-only

BMC Serial Interface Connection Mode Capabilities

Name

bmcSerialInterfaceConnectionModeCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.8

Description

Defines the connection mode capabilities of the BMC serial interface.

Syntax

DellBMCSerialConnectionModeCapabilities

Access

Read-only

BMC Serial Interface Connection Mode Settings

Name

bmcSerialInterfaceConnectionModeSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.9

Description

Defines the connection mode settings of the BMC serial interface.

Syntax

DellBMCSerialConnectionModeSettings

Access

Read-only

BMC Serial Interface Flow Control

Name

bmcSerialInterfaceFlowControl

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.10

Description

Defines the flow control type of the BMC serial interface.

Syntax

DellBMCSerialFlowControlType

Access

Read-only

BMC Serial Interface Bit Rate

Name

bmcSerialInterfaceBitRate

Object ID

1.3.6.1.4.1.674.10892.1.1900.20.1.11

Description

Defines the bit rate of the BMC serial interface.

Syntax

DellBMCSerialBitRateType

Access

Read-only

Baseboard Management Controller LAN Interface Table

Name

bmcLANInterfaceTable

Object ID

1.3.6.1.4.1.674.10892.1.1900.30

Description

Defines the Baseboard Management Controller (BMC) LAN Interface Table.

Syntax

SEQUENCE OF BmcLANInterfaceTableEntry

Access

Not accessible

BMC LAN Interface Table Entry

Name

bmcLANInterfaceTableEntry

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1

Description

Defines the Baseboard Management Controller (BMC) LAN Interface Table Entry.

Syntax

BmcLANInterfaceTableEntry

Access

Not accessible

Index

bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex, bmcLANInterfaceIndex

BMC LAN Interface Chassis Index

Name

bmcLANInterfaceChassisIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.1

Description

Defines the index (one-based) of the associated chassis.

Syntax

DellObjectRange

Access

Read-only

BMC LAN Interface BMC Index

Name

bmcLANInterfaceBMCIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.2

Description

Defines the index (one-based) of the associated BMC.

Syntax

DellObjectRange

Access

Read-only

BMC LAN Interface Index

Name

bmcLANInterfaceIndex

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.3

Description

Defines the index (one-based) of the BMC LAN interface.

Syntax

DellObjectRange

Access

Read-only

BMC LAN Interface State Capabilities

Name

bmcLANInterfaceStateCapabilities

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.4

Description

Defines the state capabilities of the BMC LAN interface.

Syntax

DellStateCapabilities

Access

Read-only

BMC LAN Interface State Settings

Name

bmcLANInterfaceStateSettings

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.5

Description

Defines the state settings of the BMC LAN interface.

Syntax

DellStateSettings

Access

Read-write

BMC LAN Interface Status

Name

bmcLANInterfaceStatus

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.6

Description

Defines the status of the BMC LAN interface.

Syntax

DellStatus

Access

Read-only

BMC LAN Interface Channel Number

Name

bmcLANInterfaceChannelNumber

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.7

Description

Defines the BMC channel number of the BMC LAN interface.

Syntax

DellUnsigned8BitRange

Access

Read-only

BMC LAN Interface IP Address Source

Name

bmcLANInterfaceIPAddressSource

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.8

Description

Defines the source type of the IP address of the BMC LAN interface.

Syntax

DellBMCLANIPAddressSourceType

Access

Read-only

BMC LAN Interface IP Address

Name

bmcLANInterfaceIPAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.9

Description

Defines the IP address of the BMC LAN interface.

Syntax

IpAddress

Access

Read-only

BMC LAN Interface Subnet Mask Address

Name

bmcLANInterfaceSubnetMaskAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.10

Description

Defines the subnet mask of the BMC LAN interface.

Syntax

IpAddress

Access

Read-only

BMC LAN Interface Default Gateway Address

Name

bmcLANInterfaceDefaultGatewayAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.11

Description

Defines the IP address of the default gateway for the BMC LAN interface.

Syntax

IpAddress

Access

Read-only

BMC LAN Interface MAC Address

Name

bmcLANInterfaceMACAddress

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.12

Description

Defines the MAC address of the BMC LAN interface.

Syntax

DellMACAddress

Access

Read-only

BMC LAN Interface Alert Community Name

Name

bmcLANInterfaceAlertCommunityName

Object ID

1.3.6.1.4.1.674.10892.1.1900.30.1.13

Description

Defines the SNMP community used for BMC LAN alerts (traps) sent on the BMC LAN interface.

Syntax

DisplayString (SIZE (0..32))

Access

Read-only


Baseboard Management Controller Group Variable Values

This section includes definitions for server administrator-specific variable values used in this section.

Table 21-1. BMC Serial Connection Mode Capabilities

Variable Name: DellBMCSerialConnectionModeCapabilities

Data Type: Integer
These values are bit masks; therefore, combination values are possible.

Possible Data Values

Meaning of Data Value

-- none(0)

No mode capabilities.

modemBasic(1)

BMC serial interface supports Modem Basic mode.

modemPPP(2)

BMC serial interface supports Modem Point to Point Protocol (PPP) mode.

modemTerminal(4)

BMC serial interface supports Modem Terminal mode.

directBasic(8)

BMC serial interface supports Direct Basic mode.

directPPP(16)

BMC serial interface supports Direct PPP mode.

directTerminal(32)

BMC serial interface supports Direct Terminal mode.

Table 21-2. BMC Serial Connection Mode Settings

Variable Name: DellBMCSerialConnectionModeSettings

Data Type: Integer
These values are bit masks; therefore, combination values are possible.

Possible Data Values

Meaning of Data Value

-- none(0)

No modes enabled.

modemBasic(1)

Modem Basic mode is enabled.

modemPPP(2)

Modem PPP mode is enabled.

modemTerminal(4)

Modem Terminal mode is enabled.

directBasic(8)

Direct Basic mode is enabled.

directPPP(16)

Direct PPP mode is enabled.

directTerminal(32)

Direct Terminal mode is enabled.

Table 21-3. BMC Serial Flow Control Type

Variable Name: DellBMCSerialFlowControlType

Data Type: Integer

Possible Data Values

Meaning of Data Value

-- none(0)

No flow control used.

rtscts(1)

RTS/CTS (hardware) flow control used.

xonXoff(2)

XON/XOFF flow control used.

Table 21-4. BMC Serial Bit Rate Type

Variable Name: DellBMCSerialBitRateType

Data Type: Integer

Possible Data Values

Meaning of Data Value

bps9600(6)

Bit rate is 9600 bps (bits per second)

bps19200(7)

Bit rate is 19200 bps

bps38400(8)

Bit rate is 38400 bps

bps57600(9)

Bit rate is 57600 bps

bps115200(10)

Bit rate is 115200 bps

Table 21-5. BMC LAN IP Address Source Type

Variable Name: DellBMCLANIPAddressSourceType

Data Type: Integer

Possible Data Values

Meaning of Data Value

-- unspecified(0)

Source is unspecified.

static(1)

IP address is static.

dhcp(2)

Dynamic Host Configuration Protocol (DHCP) used to obtain IP address.

biosOrSystemSoftware(3)

BIOS or system software provided IP Address.

other(4)

Other protocol used to obtain IP address.


Back to Contents Page

 

Notebooks | Computadores | Notebooks para Empresas | Computadores para Empresas | Workstations | Servidores | Armazenamento | Monitores | Acessórios
Direitos Autorais 1999-2009 Dell Inc.
Termos de Uso do Site | Problemas Não Resolvidos | Termos de Venda | Política de Privacidade | Sobre a Dell | Programa de Afiliados | Reciclagem Dell |Fale Conosco | Mapa do site | Feedback

Ofertas limitadas, por linha de produto, a 03 unidades para pessoa física, seja por aquisição direta e/ou entrega a ordem, e que não tenha adquirido equipamentos Dell nos últimos 04 meses, e 05 unidades para pessoa jurídica ou grupo de empresas com até 500 funcionários registrados. Os serviços de suporte pós-garantia e/ou outros serviços serão faturados em nota fiscal específica de prestação de serviços. Valores com frete não incluso. Preços com impostos para a cidade de São Paulo. Preços e condições serão válidos desde que não haja mudança, até a data de emissão da nota fiscal, da carga tributária, de preços de insumos, da cotação PTAX/BACEN do dólar norte-americano da data de conclusão do pedido, superior a 3% para insumos importados, ou outros fatores fora do controle da Dell. Clique aqui e obtenha maiores informações sobre as condições de pagamento. A partir de 01 de setembro de 2009 a Dell Computadores do Brasil emitirá a Nota Fiscal Eletrônica. Clique aqui para mais detalhes.

Promoção válida somente para a oferta anunciada e para as 100 primeiras unidades vendidas.

Em até 3 dias úteis contados do recebimento do pedido de compra on-line pela Dell, o cliente receberá um e-mail confirmando as condições de seu pedido. A Dell se reserva o direito de rever/corrigir o preço e as demais condições do negócio, comunicando ao cliente essa retificação, o qual, se não quiser manter o pedido nessa hipótese, deverá informar a Dell em até 5 dias úteis contados do recebimento da comunicação de retificação. A Dell reserva-se o direito de não concluir a venda se os equipamentos forem adquiridos para revenda.

Garantia: Garantia legal inclusa no prazo total de garantia. A garantia limitada inclui peças e mão-de-obra, sendo restrita aos produtos Dell. Os produtos de outras marcas estão sujeitos aos termos de garantia dos respectivos fabricantes. Na Garantia em Rede Autorizada, o serviço padrão é de 01 ano (incluída a garantia legal), em que o cliente, após contato telefônico com o Suporte Técnico da Dell, deverá encaminhar o seu equipamento à assistência técnica autorizada mais próxima de sua residência ou encaminhar pelos Correios, sem ônus, desde que seja guardada a caixa original do produto. Clique aqui para mais detalhes. Na Garantia à Domicílio, técnicos serão deslocados, se necessário, após consulta telefônica. O tempo de resposta dependerá da sua região geográfica e da disponibilidade imediata de recursos. Consulte o seu representante de vendas em caso de dúvida sobre qual é a garantia do seu equipamento.  Baterias de notebooks têm garantia de 1 ano. Lâmpadas dos projetores têm garantia de 90 dias. Para maiores detalhes clique aqui. A Dell não fornece garantia nem suporte técnico para FreeDOS™ nem qualquer outro sistema operacional ou aplicativo que não tenha sido instalado pela própria Dell nos computadores n Series. A Dell não garante a compatibilidade entre qualquer sistema operacional e os sistemas n Series. Para maiores informações sobre a Política de Devoluções da Dell clique aqui.

CompleteCare: Serviço de assistência técnica opcional, que cobre manutenção e substituição em caso de danos acidentais não cobertos pela garantia limitada, incluindo derramamentos, quedas, aumentos na tensão e quebra, e excluindo danos causados por atos intencionais, como fogo, roubo e perda clique aqui.

Wireless: Para a utilização da conectividade sem fio ("wireless") é necessária a aquisição de um roteador "wireless" e do serviço de banda larga no local de acesso ou da disponibilidade deste serviço em locais públicos.

Os softwares ofertados estão sujeitos aos Termos e Condições da Licença de Uso do Fabricante. Para maiores informações, consulte o site do fabricante.

Celeron, Celeron Inside, Centrino, Logotipo Centrino, Core Inside, Intel, Logotipo Intel, Intel Core, Intel Inside, Logotipo Intel Inside, Intel Viiv, Intel vPro, Itanium, Itanium Inside, Pentium, Pentium Inside, Xeon, e Xeon Inside são marcas registradas da Intel Corporation nos Estados Unidos e em outros países.

©2009 Advanced Micro Devices, Inc. Todos os direitos reservados. A sigla AMD, o logotipo de seta da AMD e as combinações resultantes disso são marcas registradas da Advanced Micro Devices, Inc. Outros nomes têm apenas propósitos informativos e podem ser marcas registradas dos seus respectivos proprietários.

Microsoft e Windows são marcas registradas da Microsoft Corporation nos EUA.

Empresa beneficiada pela Lei de Informática.

Fotos meramente ilustrativas

© 2009 Dell Inc. Todos os direitos reservados.

snEB11