The following is a list of error messages for the BMC Management Utility. In case of a functional failure, an error message will be printed to stderr. The text of the error message is listed in the Message column in Table A-1.
|
Code
|
Classification
|
Message
|
Description
|
IPMI Error
|
A1h
| Connection errors.
| Connection timeout.
Invalid authentication type.
| BMC not responding.
Authentication type error.
|
|
A2h
| Communication errors.
| Communication error.
Data error.
Not connected.
| Network stack or serial communication error.
Data packet format error.
Not connected to a remote server yet.
|
0xC6, 0xC7, 0xC8, 0xCA
|
A3h
| Authorization errors.
| Insufficient privilege for command.
Login not authorized.
| Insufficient privilege level to execute command.
Invalid BMC username/password.
| 0xD4
0x86
|
A5h
| Initialization errors.
| Authentication failure.
Access denied.
Unknown language.
Invalid IP address.
Session buffer limit exceeded.
| Request for a session from the local or remote proxy was rejected.
Trying to access the proxy from a forbidden IP address.
Unknown language code.
IP resolving error.
Length exceeds the limit of telnet input.
|
|
A6h
A8h
| Syntax errors.
| Command syntax error.
Unrecognized command.
Conflicting option.
Invalid parameter.
| Unable to parse command.
Unrecognized command.
Conflicting option (-last and -max).
Invalid parameter.
|
|
A7h
| Parameter value errors.
| Parameter out of range.
Parameter out of range (1-255).
Parameter out of range(1-65535)
Invalid data field.
Invalid index value.
First index larger than the last.
First index larger than total SEL records.
| Parameter out of range.
The value is out of range (1-255).
The value is out of range (1-65535).
Invalid data field.
Index cannot be zero or a negative number.
The first index is larger than the last.
The first index is larger than the total SEL records.
| 0xC9
0xCC
|
A8h
| H/W or F/W errors.
| Unsupported command.
Sensor not present.
Sensor command error.
Firmware error.
Destination error.
Device error.
| Unsupported operation.
Request sensor, data, or record not present.
Command illegal for specified sensor or record type.
Command response could not be provided.
Cannot deliver request to destination.
Device specific (OEM) errors.
| 0xC1
0xCB
0xCD
0xCE
0xD3
0x010x7E
|
A9h
| Processing errors (transient errors that may disappear upon retry of command).
| BMC busy.
Destination timeout error.
BMC out of storage space.
Invalid reservation ID.
Duplicate command.
SDR busy.
Device busy.
BMC unavailable.
Bad BMC state.
BMC out of sessions.
| BMC out of processing resources.
BMC timeout while processing command
BMC out of storage space required to process command.
Invalid reservation ID.
Cannot execute duplicated request.
Sensor Data Record Repository in update mode.
Device in firmware update mode.
BMC initialization in progress.
Request not supported in present BMC state.
No session slots are available for connection request.
| 0xC0
0xC3
0xC4
0xC5
0xCF
0xD0
0xD1
0xD2
0xD5
0x81, 0x82, 0x83
|
AEh
| Unexpected IPMI errors.
| Invalid LUN.
Unspecified error.
| Invalid Logical Unit Number (LUN) in request.
Unspecified error.
| 0xC2
0xFF
|
AFh
| Unknown error
| Unknown error.
| Unknown error.
|
|