The Dell PowerEdge systems baseboard management controller (BMC) monitors the system for critical events by communicating with various sensors on the system board and sends alerts and logs events when certain parameters exceed their preset thresholds. The BMC supports the industry-standard Intelligent Platform Management Interface (IPMI) specification, enabling you to configure, monitor, and recover systems remotely. The BMC provides the following features:
Access through the system's serial port and integrated NIC
Fault logging and SNMP alerting
Access to the system event log (SEL) and sensor status
Control of system functions including power on and off
Support that is independent of the system's power or operating state
Text console redirection for system setup, text-based utilities, and operating system consoles
Access to Red Hat® Enterprise Linux serial console interfaces by using serial over LAN (SOL).
Dell provides several distinct utilities and programs for accessing the BMC to perform management activities. The following BMC interfaces allow users to configure and manage your system through the BMC.
The BMC Management Utility allows remote, out-of-band LAN and/or serial port power control, event log access, and console redirection.
The Dell OpenManage Deployment Toolkit Version 1.3 BMCCFG.EXE utility provides a powerful command line configuration tool.
Dell OpenManage Server Administrator allows remote, in-band access to event logs, power control, and sensor status information and provides the ability to configure the BMC.
In addition, the BMC can be accessed by standard, off-the-shelf terminal or terminal emulator utilities that allow access to sensor status information, and power control.
Supported Systems
The BMC-management features documented in this guide are supported on the following Dell PowerEdge systems:
800
1425SC
1800
1850
1855
2800
2850
6800
6850
BMC Configuration and Management Tasks
This User's Guide documents the basic tasks needed to set up and configure the BMC on a managed system in preparation for using the BMC Management Utility. These basic tasks are described in the following sections:
Configuring the BMC
Managing the BMC
Configuring the BMC
To configure the BMC in a pre-boot environment, you can use either the BIOS BMC Setup Module or the DTK BMCCFG.EXE utility, depending on the scope of your required configuration tasks. Alternately, you can configure the BMC on a managed system with a running operating system using the Server Administrator home page GUI or CLI. See "Baseboard Management Controller Configuration" for more information.
Managing the BMC
To manage the BMC in a pre-boot environment, or to access the BMC of a nonresponsive system, you must use the BMC Management Utility. See "Using the BMC Management Utility." To configure the BMC on a system with a running operating system or to perform everyday BMC management tasks, you can use the GUI on the Server Administrator home page. See the Server Administrator Version 2.0 User's Guidefor more information about using Server Administrator to manage your system's BMC functions. Figure 1-1 shows the configuration matrix for BMC.
Figure 1-1. BMC Configuration Matrix
BMC Action on Alert
If you plan to use your system's BMC to send BMC alerts, you must follow the BMC Action on Alert configuration guidelines listed in Table 1-1.
Table 1-1. BMC Action on Alert Configuration Guidelines
Features
Connection Medium
BMC Configuration Tools
Basic Configuration Tasks
BMC Management Tools
System Reset
System Power Off
System Power Cycle
Accessed over a shared LAN
DTK (pre-operating system environment)
Server Administrator
Enable platform events
Enable alert actions
NA
Basic BMC Alerting Over a Shared LAN
If you plan to use your system's BMC to only monitor BMC Alerts using IT Assistant, you will need to follow the BMC configuration guidelines listed in Table 1-2.
Table 1-2. BMC LAN Alerting Configuration Guidelines
Features
Connection Medium
BMC Configuration Tools
Basic Configuration Tasks
BMC Management Tools
SNMP Traps
Accessed over a shared LAN
BMC Setup Module (pre-operating system environment)
DTK (pre-operating system environment)
Server Administrator
Enable alerting on the managed system
Configure the IP address, Subnet mask, and Gateway on the managed system
Configure the Alert destination IP address
Enable VLAN (optional)
IT Assistant
IPMI Shell Over a Shared LAN
If you plan to use the BMC Management Utility's IPMI Shell to access your system's BMC over a shared LAN, you must follow the BMC configuration guidelines listed in Table 1-3.
Table 1-3. BMC LAN Access Configuration Guidelines
Features
Connection Medium
BMC Configuration Tools
Basic Configuration Tasks
BMC Management Tools
Remote SEL access
Power control
System identification
System information
Accessed over a shared LAN
BMC Setup Module (pre-operating system environment)
DTK (pre-operating system environment)
Server Administrator
Configure BMC user(s)
Enable LAN on managed system
Configure the IP address, Subnet mask, and Gateway on the managed system
Enable VLAN (optional)
IPMI Shell
IPMI Shell Over the Serial Cable
If you plan to use the BMC Management Utility's IPMI Shell or a text console redirection to access your system's BMC over a serial cable, you must follow the BMC configuration guidelines listed in Table 1-4.
Table 1-4. BMC Serial Configuration Guidelines
Features
Connection Medium
BMC Configuration Tools
Basic Configuration Tasks
BMC Management Tools
Remote SEL access
Power control
System identification
System information
Accessed through the serial channel by using a null modem cable
BIOS (pre-operating system environment)
DTK (pre-operating system environment)
Server Administrator (to enable BMC serial only)
Configure BMC user(s)
Enable BMC serial in BIOS
Set BMC serial to either Basic mode or Terminal mode
Set the Baud rate (9600 or 19200)
IPMI Shell (Basic mode only)
Terminal emulation (Terminal mode only)
SOL Proxy Over a Shared LAN
If you plan to use the BMC Management Utility's SOL Proxy to access your system's BMC over a shared LAN, you must follow the BMC configuration guidelines listed in Table 1-5.
Table 1-5. BMC SOL Configuration Guidelines
Features
Connection Medium
BMC Configuration Tools
Basic Configuration Tasks
BMC Management Tools
Text Utility console redirection
Remote BIOS setup
Microsoft text console redirection
Red Hat Enterprise Linux text console redirection
Accessed over a shared LAN
BIOS (pre-operating system environment)
BMC Setup Module (pre-operating system environment)
DTK (pre-operating system environment)
Server Administrator (to enable BMC serial only)
Configure BMC user(s)
Enable LAN on the managed system
Configure the IP address, Subnet mask, and Gateway on the managed system
Enable VLAN (optional)
Enable BMC NIC in BIOS
Configure the BIOS text console redirection
Set the Baud rate (9600 or 19200) and the terminal emulation type (VT100 or ANSI)
SOL Proxy
Microsoft text console redirection
Red Hat Enterprise Linux text console redirection
BMC Configuration and Management Tools
Using the BMC Setup Module
The BMC Setup Module provides basic BMC setup and configuration functions that can be accessed during system boot. Use the BMC Setup Module for initial BMC setup and configuration only. For advanced configuration tasks, you must use the Deployment Toolkit Version 1.3 BMCCFG.EXE utility or Server Administrator Version 2.0. See your system User's Guide for additional information about the BMC Setup Module.
Using the Deployment Toolkit
The Deployment Toolkit (DTK) Version 1.3 BMCCFG.EXE utility provides a powerful DOS-based command-line interface for locally configuring your system's BMC as part of an initial deployment. Use the BMCCFG.EXE utility to set all supported BMC features. In addition, you can use the DTK utilities as part of a scripted deployment to multiple similar systems. To use the BMCCFG.EXE utility, you must perform the following tasks:
Download the DTK executable and save the utilities to your hard drive.
Set up a bootable diskette or CD that contains a copy of the BMCCFG.EXE utility.
Locally configure BMC on the managed system.
See the Deployment Toolkit Version 1.3 User's Guide and Command Line Interface Reference Guide for more information about using the BMCCFG.EXE utility to configure and manage your system BMC.
Using the BMC Management Utility
The BMC Management Utility provides a command-line, remote management station to manage BMC-supported functions. Use the BMC Management Utility to manage your BMC from a remote management station and as your managed system's emergency management console. The utility gives you the option of using either a command line interface (IPMI Shell) or a serial over LAN proxy (SOL Proxy) to access and manage the BMC. To use the BMC Management Utility, you must perform the following tasks:
NOTE: You must first configure your BMC with the BMC Setup Module, the Deployment Toolkit
BMCCFG.EXE utility, or Server Administrator before you can use the BMC Management Utility.
Configure BMC using the BMC Setup Module, the Deployment Toolkit BMCCFG.EXE utility, or Server Administrator.
Install the BMC Management Utility on a management station.
See "Configuring Your Managed System" for instructions on configuring the BMC on a managed system in preparation for using the BMC Management Utility. For complete instructions about using the BMC Management Utility to manage your system BMC, see "Using the BMC Management Utility."
Using Server Administrator
Server Administrator Version 2.0 provides a convenient and easy-to-use graphical user interface for remotely configuring or managing your system's BMC on a system running a supported operating system. You can use the Server Administrator Instrumentation Service to configure the most relevant BMC features, such as Platform Event Filter (PEF) parameters and alert destinations. In addition, Server Administrator can be used as command line interface. Server Administrator requires that the system has an operating system installed and functioning. As a result, Server Administrator is best suited for everyday BMC management tasks, and is not an option for performing pre-boot setup or accessing the BMC as a emergency management console. To use Server Administrator, you must perform the following tasks:
Install Server Administrator on the managed system.
Remotely access the Server Administrator home page from a supported browser on a management station.
Remotely configure BMC on the managed system.
See the Server Administrator Version 2.0 User's Guide and Command line Interface User's Guide for more information about using Server Administrator to configure and manage your system BMC.
Other Dell Documents You May Need
In addition to this User's Guide, you can find the following guides either on the Dell Support website at support.dell.com or on the documentation CD:
The Dell OpenManage Quick Installation Guide provides additional information about installing the BMC Management Utility on a management station.
The Dell OpenManage Server Administrator Version 2.0 User's Guide provides additional information about using Server Administrator to manage your system's BMC.
The Dell OpenManage Deployment Toolkit Version 1.3 User's Guide provides additional information about installing and using the Deployment Toolkit utilities.
The Dell OpenManage Deployment Toolkit Version 1.3 Command Line Interface Reference Guide provides a complete list of all valid BMC-related command-line options, suboptions, and arguments.
The Dell OpenManage IT Assistant User's Guide Version 7.0 provides information about how to monitor and manage a large number of client and server systems on a local area network (LAN) or wide area network (WAN).
Your Dell system User's Guide provides supplemental information about configuring your BIOS settings with the System Setup Program and your BMC with the BMC Setup Module, as well as instructions for configuring your system to use console redirection.
Additionally, the Dell OpenManage readme.txt file provides the latest available information for the installation and operation of the programs and utilities used to manage your system through the BMC. The readme is available on the Dell OpenManage Systems Management Consoles CD and on the Dell Support website at support.dell.com.
Obtaining Technical Assistance
If at any time you do not understand a procedure described in this guide or if your product does not perform as expected, help tools are available to assist you. For more information about these help tools, see "Getting Help" in your system's Installation and Troubleshooting Guide.
Additionally, Dell Enterprise Training and Certification is available; see www.dell.com/training for more information. This service may not be offered in all locations.
*Offers subject to change. Taxes, shipping, handling and other fees apply. U.S. Dell Small Business new purchases only. LIMIT 5 DISCOUNTED OR PROMOTIONAL ITEMS PER CUSTOMER. LIMIT 5 VOSTRO OR INSPIRON UNITS PER CUSTOMER. Dell reserves right to cancel orders arising from pricing or other errors.