All possible Platform Event Filter (PEF) Alert Messages along with a
description of each event are listed in
Table B-1.
|
Event
|
Description
|
Fan Probe Failure
| The fan is running too slow or not at all.
|
Voltage Probe Failure
| The voltage is too low for proper
operation.
|
Discrete Voltage Probe Failure
| The voltage is too low for proper
operation.
|
Temperature Probe Warning
| The temperature is approaching excessively
high or low limits.
|
Temperature Probe Failure
| The temperature is either too high or too
low for proper operation.
|
Chassis Intrusion Detected
| The system chassis has been opened.
|
Redundancy (PS or Fan) Degraded
| Redundancy for the fans and/or power
supplies has been reduced.
|
Redundancy (PS or Fan) Lost
| No redundancy remains for the system's
fans and/or power supplies.
|
Processor Warning
| A processor is running at less than peak
performance or speed.
|
Processor Failure
| A processor has failed.
|
PPS/VRM/DCtoDC Warning
| The power supply, voltage regulator
module, or DC-to-DC converter is pending a failure condition.
|
Power Supply/VRM/D2D Failure
| The power supply, voltage regulator
module, or DC-to-DC converter has failed.
|
Hardware log is full or emptied
| Either an empty or a full hardware log
requires administrator attention.
|
Automatic System Recovery
| The system is hung or is not responding
and is taking an action configured by Automatic System Recovery.
|
System Power Probe Warning
| The system is setting actions when a power
consumption probe detects a warning value.
|
System Power Probe Failure
| The system is setting actions when a power
consumption probe detects a failure value.
|