packet_sizeNumber of bytes in a packet, from 56 to 1472 bytes. The actual packet size is eight bytes larger than the size specified because the switch adds header information.
packet_countNumber of packets to send, from 1 to 65535 packets. If 0 is entered it pings until stopped.
time_outTimeout in milliseconds to wait for each reply, from 1 to 65535 milliseconds.
Default Configuration
The default packet size is 56 bytes.
The default packet count is 4 packets.
The default time-out is 1000 milliseconds.
Command Mode
User EXEC Mode
User Guidelines
Press ESC to stop pinging. Following are sample results of the ping command:
Destination does not respondIf the host does not respond, no answer from host appears in ten seconds.
Destination unreachableThe gateway for this destination indicates that the destination is unreachable.
Network or host unreachableThe switch found no corresponding entry in the route table.
Examples
The following example displays a ping to IP address 10.1.1.1.
Console> ping 10.1.1.1
64 bytes from 10.1.1.1: icmp_seq=0. time=11 ms
64 bytes from 10.1.1.1: icmp_seq=1. time=8 ms
64 bytes from 10.1.1.1: icmp_seq=2. time=8 ms
64 bytes from 10.1.1.1: icmp_seq=3. time=7 ms
64 bytes from 10.1.1.1: icmp_seq=4. time=11 ms
64 bytes from 10.1.1.1: icmp_seq=5. time=7 ms
64 bytes from 10.1.1.1: icmp_seq=6. time=7 ms
^C
----10.1.1.1 PING Statistics----
7 packets transmitted, 7 packets received, 0% packet loss
round-trip (ms) min/avg/max = 7/8/11
Console>
reload
Use the reload user EXEC command to reload the operating system.
Syntax
reload
Default Configuration
This command has no default configuration.
Command Mode
Privileged EXEC Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays the prompt when entering the reload command.
Console >reload
This command will reset the whole system and disconnect your
telnet session.
Do you want to continue (y/n) [n]?
clock set
Use the clock set user EXEC command to manually set the system clock.
Syntax
clock set hh:mm:ss day month year
or
clock sethh:mm:ss month day year
hh:mm:ssCurrent time in hours (military format), minutes, and seconds (0-23, mm: 0-59, ss: 0-59).
dayCurrent day (by date) in the month (1-31).
monthCurrent month using the first three letters by name (Jan, ... Dec).
yearCurrent year (1998-2097).
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
This device clock is not a Real Time Clock (RTC). When the device is rebooted or restarted, the clock setting is deleted.
Examples
The following example sets the system time.
Console> clock set 13:32:00 7 Mar 2002
hostname
Use the hostname global configuration command to specify or modify the device host name. To restore the default host name, use the no form of the command.
Syntax
hostnamename
no hostname
nameThe name of this host.
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example specifies dell as the device host name.
Console (config)# hostname dell
asset-tag
Use the asset-tag global configuration command to specify the device asset-tag. Use the no form of this command to restore the default host name.
Syntax
asset-tag [unitunit] tag
no asset-tag [unitunit]
unitunitUnit number. If unspecified defaults to the master unit number.
tagThe device asset-tag.
Default Configuration
This command has no default configuration.
Command Mode
Global Configuration Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example specifies the device asset tag.
Console (config)# asset-tag 45456
stack order
Use the stack order global configuration command to configure the unit physical order in the stack. To return to the default value, use the no form of this command.
Syntax
stack order order1 order2 {order3 ...}
no stack order
order1 order2 {order3 ...}Unit order. All the units in the stack are configured in the same command.
Default Configuration
The default value is the unit number.
Command Mode
Global Configuration Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example configures the device 2 as the first unit and device 1 as the second unit in the stack.
Console (config)# stack order 2 1
show users
Use the show users user EXEC command to display information about the active users.
Syntax
show users
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays information about the active users.
Console> show users
Username Idle Time Remote IP Protocol
----------- --------- --------- ---------
Bob 00:00:00 Serial
Betty 00:08:19 172.16.0.1 Telnet
Robert - 172.16.0.8 HTTP
show clock
Use the show clock user EXEC command to display the time and date from the system clock.
Syntax
show clock
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays the time and date from the system clock.
Console> show clock
15:29:03 Jun 17 2002
show system
Use the show system user EXEC command to display system information.
Syntax
show system [unitunit]
unitunitUnit number. If unspecified, defaults to the master unit number.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays the system information.
Console> show system
System Description: Corporate
System Up Time (days,hour:min:sec): 1,22:38:21
System Contact:
System Name: Console 1
System location:
power supply status : OK
MAC Address: xxxx.xxxx.xxxx
Sys Object ID:
show version
Use the show version user EXEC command to display the system version information.
Syntax
show version [unitunit]
unitunitUnit number. If unspecified defaults to the master unit number.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
There are no user guidelines for this command.
Examples
The following example displays a system version (this version number is only for demonstration purposes).
Console> show version
SW version x.xxx (date xx-xxx-xxxx time 17:34:19)
Boot version x.xxx (date xx-xxx-xxxx time 11:48:21)
HW version x.x.x
Unit SW version Boot version HW version
----- ---------- ------------ ------------
1 3.131 2.178 1.0.0
2 3.131 2.178 1.0.0
show system id
Use the show system id user EXEC command to display the system identification information.
Syntax
show system id [unitunit]
unitunitUnit number. If unspecified, defaults to the master unit number.
Default Configuration
This command has no default configuration.
Command Mode
User EXEC Mode
User Guidelines
The tag information is on a device by device basis.
Examples
The following example displays the system identification information.
Ofertas limitadas, por linha de produto, a 03 unidades para pessoa física, seja por aquisição direta e/ou entrega a ordem, e que não tenha adquirido equipamentos Dell nos últimos 04 meses, e 05 unidades para pessoa jurídica ou grupo de empresas com até 500 funcionários registrados. Os serviços de suporte pós-garantia e/ou outros serviços serão faturados em nota fiscal específica de prestação de serviços. Valores com frete não incluso. Preços com impostos para a cidade de São Paulo. Preços e condições serão válidos desde que não haja mudança, até a data de emissão da nota fiscal, da carga tributária, de preços de insumos, da cotação PTAX/BACEN do dólar norte-americano da data de conclusão do pedido, superior a 3% para insumos importados, ou outros fatores fora do controle da Dell. Clique aqui e obtenha maiores informações sobre as condições de pagamento. A partir de 01 de setembro de 2009 a Dell Computadores do Brasil emitirá a Nota Fiscal Eletrônica. Clique aqui para mais detalhes.
Promoção válida somente para a oferta anunciada e para as 100 primeiras unidades vendidas.
Em até 3 dias úteis contados do recebimento do pedido de compra on-line pela Dell, o cliente receberá um e-mail confirmando as condições de seu pedido. A Dell se reserva o direito de rever/corrigir o preço e as demais condições do negócio, comunicando ao cliente essa retificação, o qual, se não quiser manter o pedido nessa hipótese, deverá informar a Dell em até 5 dias úteis contados do recebimento da comunicação de retificação. A Dell reserva-se o direito de não concluir a venda se os equipamentos forem adquiridos para revenda.
Garantia: Garantia legal inclusa no prazo total de garantia. A garantia limitada inclui peças e mão-de-obra, sendo restrita aos produtos Dell. Os produtos de outras marcas estão sujeitos aos termos de garantia dos respectivos fabricantes. Na Garantia em Rede Autorizada, o serviço padrão é de 01 ano (incluída a garantia legal), em que o cliente, após contato telefônico com o Suporte Técnico da Dell, deverá encaminhar o seu equipamento à assistência técnica autorizada mais próxima de sua residência ou encaminhar pelos Correios, sem ônus, desde que seja guardada a caixa original do produto. Clique aqui para mais detalhes. Na Garantia à Domicílio, técnicos serão deslocados, se necessário, após consulta telefônica. O tempo de resposta dependerá da sua região geográfica e da disponibilidade imediata de recursos. Consulte o seu representante de vendas em caso de dúvida sobre qual é a garantia do seu equipamento. Baterias de notebooks têm garantia de 1 ano. Lâmpadas dos projetores têm garantia de 90 dias. Para maiores detalhes clique aqui. A Dell não fornece garantia nem suporte técnico para FreeDOS™ nem qualquer outro sistema operacional ou aplicativo que não tenha sido instalado pela própria Dell nos computadores n Series. A Dell não garante a compatibilidade entre qualquer sistema operacional e os sistemas n Series. Para maiores informações sobre a Política de Devoluções da Dell clique aqui.
CompleteCare: Serviço de assistência técnica opcional, que cobre manutenção e substituição em caso de danos acidentais não cobertos pela garantia limitada, incluindo derramamentos, quedas, aumentos na tensão e quebra, e excluindo danos causados por atos intencionais, como fogo, roubo e perda clique aqui.
Wireless: Para a utilização da conectividade sem fio ("wireless") é necessária a aquisição de um roteador "wireless" e do serviço de banda larga no local de acesso ou da disponibilidade deste serviço em locais públicos.
Os softwares ofertados estão sujeitos aos Termos e Condições da Licença de Uso do Fabricante. Para maiores informações, consulte o site do fabricante.
Celeron, Celeron Inside, Centrino, Logotipo Centrino, Core Inside, Intel, Logotipo Intel, Intel Core, Intel Inside, Logotipo Intel Inside, Intel Viiv, Intel vPro, Itanium, Itanium Inside, Pentium, Pentium Inside, Xeon, e Xeon Inside são marcas registradas da Intel Corporation nos Estados Unidos e em outros países.