Tag-based IEEE 802.1p Class-of-Service with two priority queues per port
IEEE 802.3x PAUSE frames flow control in full-duplex operation
Automatic negotiation for speed and full- and half-duplex mode on all ports
Backpressure flow control in half-duplex operation
Collision detection on all ports
Auto MDI/MDIX
8K MAC address entries supported
Comprehensive LED indicator panel to monitor overall switching condition
19-inch rackmountable and wallmountable, standard 1U chassis
Internal power supply
Package Contents
Before you install a switch, verify that your package contains the following items:
Switch
Self-adhesive rubber pads for desktop installation
Kit for 19-inch rack installation
Kit for wallmount installation of 16- and 24-port switches
PowerConnect 2216/2224/2324 Switches CD
AC power cord
Front Panel Indicators
Your PowerConnect switch contains two rows of LEDS that provide information about connection speed, data activity, and duplex operation mode.
Power (POWER) LED
Green The switch is powered on.
Off The switch is off.
10/100 Ports Link/Activity (SPD/LNK/ACT) LED
Steady green A 100-Mbps link has been established, but no data is being transmitted or received.
Blinking green A 100-Mbps link has been established and data is being transmitted or received.
Steady amber A 10-Mbps link has been established, but no data is being transmitted or received.
Blinking amber A 10-Mbps link has been established and data is being transmitted or received.
Off No link has been established.
10/100/1000 Ports Link/Activity (SPD/LNK/ACT) LED (2324 only)
Steady green A 1000-Mbps link has been established, but no data is being transmitted or received.
Blinking green A 1000-Mbps link has been established and data is being transmitted or received.
Steady amber A 10-Mbps or 100-Mbps link has been established, but no data is being transmitted or received.
Blinking amber A 10-Mbps or 100-Mbps link has been established and data is being transmitted or received.
Off No link has been established.
Duplex Mode/Collisions (FDX/HDX) LED
Steady green The port is operating in full-duplex mode.
Blinking green Collisions are occurring on the port.
Off The port is operating in half-duplex mode.
Figure 1-1. PowerConnect 2216
Figure 1-2. PowerConnect 2224
Figure 1-3. PowerConnect 2324
Connecting Devices
RJ-45 Switch Ports
RJ-45 connectors are located on the front panel of the switch.
NOTE: Ensure that Category 5E (CAT 5E) cabling is used for connecting devices at 1000-Mbps Gigabit
Ethernet speed.
All ports can negotiate full- and half-duplex modes automatically. These switching ports allow users to connect the switches to 10Base-T and 100Base-T on ports 1-16 (2216), ports 1-24 (2224, 2324) and 1000Base-T devices on uplink ports 25 and 26 on the 2324.
Connecting Two or More Switches Together
Each port supports Auto MDI and MDIX functionality. When cascading with other switches or hubs, each port can connect directly to a switch or hub with straight-through twisted-pair cable (see Figure 1-4).
NOTE: Do not connect two switches together with more than one cable. Using multiple cables to
connect switches can create a loop and cause collisions.
Figure 1-4. Cascading Switches
Connecting Switches to Other Devices
By connecting a switch to other devices, you can form a small network. All the RJ-45 ports support Auto MDI/MDIX and therefore automatically detect the type of cable used to connect the network device. Crossover or straight-through networking cables can be used to connect PCs as well as other networking devices like hubs or routers to the switch. All ports on the switch automatically negotiate speed and whether to operate in full duplex or half duplex.
Typical Deployments
Your switch can be deployed in small and large workgroups. Figure 1-5 depicts a typical small workgroup network that has a limited number of attached devices. Figure 1-6 Figure 1.6 depicts a typical large workgroup that has several groups of individuals not all working in the same physical area.
Figure 1-5. Small Workgroup
Figure 1-6. Large Workgroup
Class-of-Service
The switch supports tag-based prioritization following the IEEE 802.1p standard. The eight levels of IEEE 802.1p priority are mapped to the two priority queues of each port. For each port, the two priority queues are scheduled following a Weighted Round Robin scheme.
Table 1-1. Tag-Based Prioritization
IEEE 802.1p Priority
Priority Queue
Scheduling Weight
0-3
0
1
4-7
1
4
NOTE: The IEEE 802.1p priority information is part of the IEEE 802.1q tag that also defines VLAN
memberships. The switches will ignore the VLAN membership information in the tag (that is, all ports are
part of all VLANs), but will preserve the full tag informationincluding packet priority and VLAN ID
when transmitting the packet at the destination port.
Mounting Kit Instructions
The switches come with mounting brackets and screws for rackmounting or wallmounting and rubber feet for stationing on a flat surface.
Installing the Switch on a Flat Surface
The switch can be installed on any appropriate level surface that can safely support the weight of the switches and their attached cables. There must be adequate space around the switch for ventilation and access to cable connectors.
To install the switch on a flat surface, complete the following steps:
Set the switch on the flat surface and check for proper ventilation.
Allow at least 5.1 cm (2 inches) on each side for proper ventilation and 12.7 cm (5 inches) at the back for power cable clearance.
Attach rubber feet on each marked location on the bottom of the chassis.
The rubber feet are optional, but are recommended to keep the switch from slipping.
Installing the Switch in a Rack
The switch can be installed in Dell PowerEdge racks, which are 48.3 cm (19 inches). It can also be installed in most other standard 19-inch racks and most telco two-post racks.
NOTE: Do not install rubber feet on the switch if you are rackmounting the switch.
To install the switch in a rack, complete the following steps:
Use the supplied screws to attach a mounting bracket to each side of the switch (see
Figure 1-7).
Figure 1-7. Brackets for Rack Installation
Install the cage nuts onto the mounting rails of your rack, if your rack requires them.
NOTE: Additional screws are provided for racks that have threaded mounting holes.
Position the switch in the rack and align the holes in the mounting bracket with the holes in
the rack.
Insert and tighten two screws appropriate for your rack through each of the mounting
brackets.
Installing the Switch on a Wall
To mount the switch on a wall, complete the following steps:
Ensure that the mounting point meets the following requirements:
The wall surface must be capable of supporting the switch.
Allow at least 5.1 cm (2 inches) on each side for proper ventilation and 12.7 cm (5 inches) at the back for power cable clearance.
The location must not be located in direct sunlight.
The location must not be within 2 feet of any heating vents, nor should any area heating vent point toward the unit.
The location must be ventilated to prevent heat buildup.
Do not locate the switch where there may be data or electrical cabling located directly behind the unit.
The power cable must reach an outlet.
Use the supplied screws to attach a mounting bracket to each side of the switch (see
Figure 1-8).
Figure 1-8. Brackets for Wall Installation
Place the switch against the wall and mark the wall through the holes of the brackets.
Drill holes in the wall for the brackets and install the appropriate mounting hardware (not
supplied).
Place the switch against the wall so that the bracket holes align with the holes in the wall.
Insert and tighten the screws through each of the mounting brackets.
Technical Information
Table 1-2. Specifications
Network Protocol and Standards Compatibility
IEEE 802.3 CSMA/CD
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3z/ab 1000Base-T
IEEE 802.3x Flow Control
IEEE 802.3p Priority
Interface
RJ-45 connectors
Power Supply
PowerConnect 2216
Supply voltage: 100-240 VAC Frequency: 50-60 Hz Current consumption: 0.4A
PowerConnect 2224
Supply voltage: 100-240 VAC Frequency: 50-60 Hz Current consumption: 0.75A
PowerConnect 2324
Supply voltage: 100-240 VAC Frequency: 50-60 Hz Current consumption: 0.75A
Physical Dimensions
PowerConnect 2216
266 x 161 x 43 mm (W x D x H) 10.5 x 6.3 x 1.7 inches Unit Weight: 3.0 Lbs Packaged Weight: 3.3 Lbs (6 per container)
PowerConnect 2224
328 x 231 x 43 mm (W x D x H) 13 x 9 x 1.7 inches Unit Weight: 4.8 Lbs Packaged Weight: 5.24 Lbs (5 per container)
PowerConnect 2324
328 x 231 x 43 mm (W x D x H) 13 x 9 x 1.7 inches Unit Weight: 5.1 Lbs Packaged Weight: 5.46 Lbs (5 per container)